Open Access

Table 1

Elemental composition (%) of COPR in this study and literature data for materials from other sites (major elements (Si, Al, Fe, Ca, Mg, Na, K), minor elements (P, S, Cr), loss of ignition (LOI), and water content %H (in percent)).

Composition élémentaire (%) des charrées de chrome dans cette étude et comparaison avec des données de la littérature.

  This study and Lehoux et al. (2017) Matern et al. (2016) Földi et al. (2013) Wazne et al. (2007) Hillier et al. (2003)
T-RX T-RX2 T-RX3 T-RX4 PZ2 Rania Chiwali Kanpur #2502 Hudson County, New Jersey Glasgow
Site 2 Site 4 Site 7
LOI 21.4 22.9 18.1 23.5 15 20 13.2 16.4   19.1 16.2 16.8
Si 13.4 7.5 17.8 7.5 6.1 3.9 4.91 2.6 1.98 4.5 2.3 2.4
Ca 10.7 12.7 8.9 12.6 16.3 22.5 22.7 23.2 23.9 18.1 16.2 22.9
Fe 6.9 8.2 5.2 8.1 14.7 7.32 8.38 7 11.8 8.3 10.1 12.7
Mg 5.7 8.6 3.6 8.7 3.4 4.73 6.04 5.8 6.1 12.6 15.3 7.1
Al 4.8 4.1 4.4 4.1 5 4.43 4.88 4.6 4.6 3.9 4.3 5.5
Cr 1.4 2.2 1.3 2.2 1.3 7.98 7.55 10.9 2.71 4 5.9 4.3
P 1 0.4 1.4 0.4 0.01 0.01 0.04
S 0.9 0.6 0.7 0.7 0.03 0.04 0.02 0.34 0.44 0.25 0.25
Na 0.7 1.4 1.3 1.5 0.437 0.68 0.36 0.37 0.2 0.14 0.11
K 0.6 0.4 0.9 0.4 0.067 0.1 0.02 0.03 < 0.05 < 0.05 < 0.05
%H 20.2 38.2 34.5 34.5 38        
pH 11.8 11.5 10.2 11.9 11.6 12.4 12.4 12.6        

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.